Microcell Double Safety Beam
Set, 10 Meter Cables
TECHNOLOGY | Active Infrared |
---|---|
DETECTION MODE | Presence (Beam Interruption) |
MIN. MOUNTING HEIGHT | 12” from floor |
MIN. DISTANCE BETWEEN BEAMS | 12” (crossed beams) |
MIN. RANGE OF DETECTION | 3’ |
MAX. RANGE OF DETECTION | 15’ |
ALIGNMENT TOLERANCE | 8° |
RESPONSE TIME | ≤ 40 ms |
HOLD TIME | 300 ms |
SUPPLY VOLTAGE | 12 – 24 VAC; ±10% 12 – 24 VDC; –5% / 30% |
CURRENT CONSUMPTION | < 100 mA |
OUTPUT CONTACT RATING MAX. CONTACT VOLTAGE MAX. CONTACT CURRENT MAX. SWITCHING POWER | 1 Relay (NC / NO contacts) 50 VAC / VDC 1 A 30 W (DC) / 60 VA (AC) |
OPERATING TEMPERATURE | -30 – 131 °F |
IMMUNITY SUNLIGHT INCANDESCENT LAMP ELECTROMAGNETIC COMPATIBILITY | 75,000 lux 25,000 lux @ 8° angle According to 89 / 336 EEC |
DIMENSIONS HEAD BODY HEAD HARNESS CONTROL BOARD | < 15⁄32” (L embed) × 15⁄32” (ø) 5⁄8” (ø) 3 1⁄33” (W) × 1 2⁄25” (H) × 2 1⁄33” (D) |
CABLE LENGTH | 18’ (standard) 32’ (optional) |
MATERIAL | ABS |
DEGREE OF PROTECTION | NEMA 4 / IP65 (beam heads) |
Downloads
Sliding Door Wiring Matrix Application Note
Application Note – Sliding Door Wiring Matrix
Microcell User Guide
MICROCELL ADAPTER User Guide
Weight | 1 lbs |
---|