Quadscan I safety sensor, 1 module, 34.5 inch end cap to end cap
TECHNOLOGY | Active Infrared |
---|---|
MOUNTING HEIGHT | 3’ 7” – 9’ 10” |
MAX. NUMBER OF MODULES | 4; up to 6 if 24 VDC |
DETECTION FIELD AT FINISHED FLOOR | 15 ¾” (W) × 2 ¾” (D) @ 78” (H) |
RANGE ADJUSTMENT | Mechanical range adjustment screw |
REACTION TIME | 64 ms (typical) |
INPUT MAX. CONTACT VOLTAGE VOLTAGE THRESHOLD | 1 optocoupler (free of potential contact) 30 V High: > 10 VDC; Low: < 1 VDC |
OUTPUT MAX. CONTACT VOLTAGE MAX. CONTACT CURRENT MAX. SWITCHING POWER | 2 Relays Free of Potential Contact 42 VAC / VDC 1 A (Resistive) 30 W (DC); 60 VA (AC) |
SUPPLY VOLTAGE | 12 V – 24 VAC ±10% 12 V – 30 VDC −5%; 10% |
MAX. POWER CONSUMPTION (EACH MODULE) | 65 mA @ 24 VAC 75 mA @ 24 VDC |
OBJECT REFLECTIVITY | Min. 5% @ IR-wavelength of 850 nm |
DEGREE OF PROTECTION | IP53 |
TEMPERATURE RANGE | -13 – 131 ºF (-25 – 55 ºC) 0 – 95% Relative Humidity, Non-condensing |
NORM CONFORMANCE | EMC 2004/108/EC; MD 2006/42/EC; EN ISO 13849-1:2008; Performance Level CAT 2; EN 12978 |
Downloads
Weight | 1 lbs |
---|