LZR FLATSCAN W RIGHT BLACK
TECHNOLOGY | LASER scanner, time-of-flight measurement, background analysis |
---|---|
DETECTION MODE | Presence |
MAX. DETECTION RANGE | 13’ (diagonal) (e.g. @ 40’ width, max. height is 16’) |
NUMBER OF CURTAINS | 1 |
MEASUREMENT POINTS | 400 |
ANGULAR RESOLUTION | 0.27° |
ANGULAR COVERAGE | 110° |
MIN. OBJECT SIZE | ¾” (depending on the settings and the installation) |
OPTICAL CHARACTERISTICS | IR LASER, Class 1 wavelength: 905 nm output power: < 0.1mW |
SUPPLY VOLTAGE | 12 – 24 VDC ±15% The equipment must be powered by a SELV limited power source ensuring double insulation between primary voltages and the Equipment supply. The supply current should be limited to 1.5A. |
POWER CONSUMPTION | ≤ 2 W |
TYP. RESPONSE TIME | 400 ms |
PEAK CURRENT AT POWER-ON | 0.8A (max. 20 ms @ 24 VDC) |
CABLE LENGTH | 16.4’ |
OUTPUT MAX. SWITCHING VOLTAGE MAX. SWITCHING CURRENT | 2 solid state relays (galvanic isolation - polarity free) 42 VAC/VDC 100 mA |
INPUT MAX. CONTACT VOLTAGE VOLTAGE THRESHOLD | 1 optocoupler (galvanic isolated - polarity free) 30 V DC (over-voltage protected) Log. H: >8 VDC Log. L: <3 VDC |
LED SIGNALS | 1 tri-colored LED: detection/output status |
DIMENSIONS | 5 3⁄5” (L) × 3 11⁄32” (H) × 1 ⅓” (D) (mounting base adds ½”) |
MATERIAL / COLOR | PC, ASA / black |
TILT ANGLES | -2 – 6° (with mounting base) 2 – 10° (without mounting base) |
PROTECTION DEGREE | IP54 |
TEMPERATURE RANGE | -22 – 140 °F if powered 14 – 140 °F without power |
HUMIDITY | 0 – 95% non-condensing |
VIBRATIONS | < 2 G |
COMPLIANCE | IEC 60335-2-103 ISO 13849-1 (PL “d”); IEC 61508 (SIL2) |