LZR FLATSCAN W RIGHT BLACK
| TECHNOLOGY | LASER scanner, time-of-flight measurement, background analysis |
|---|---|
| DETECTION MODE | Presence |
| MAX. DETECTION RANGE | 13’ (diagonal) (e.g. @ 40’ width, max. height is 16’) |
| NUMBER OF CURTAINS | 1 |
| MEASUREMENT POINTS | 400 |
| ANGULAR RESOLUTION | 0.27° |
| ANGULAR COVERAGE | 110° |
| MIN. OBJECT SIZE | ¾” (depending on the settings and the installation) |
| OPTICAL CHARACTERISTICS | IR LASER, Class 1 wavelength: 905 nm output power: < 0.1mW |
| SUPPLY VOLTAGE | 12 – 24 VDC ±15% The equipment must be powered by a SELV limited power source ensuring double insulation between primary voltages and the Equipment supply. The supply current should be limited to 1.5A. |
| POWER CONSUMPTION | ≤ 2 W |
| TYP. RESPONSE TIME | 400 ms |
| PEAK CURRENT AT POWER-ON | 0.8A (max. 20 ms @ 24 VDC) |
| CABLE LENGTH | 16.4’ |
| OUTPUT MAX. SWITCHING VOLTAGE MAX. SWITCHING CURRENT | 2 solid state relays (galvanic isolation - polarity free) 42 VAC/VDC 100 mA |
| INPUT MAX. CONTACT VOLTAGE VOLTAGE THRESHOLD | 1 optocoupler (galvanic isolated - polarity free) 30 V DC (over-voltage protected) Log. H: >8 VDC Log. L: <3 VDC |
| LED SIGNALS | 1 tri-colored LED: detection/output status |
| DIMENSIONS | 5 3⁄5” (L) × 3 11⁄32” (H) × 1 ⅓” (D) (mounting base adds ½”) |
| MATERIAL / COLOR | PC, ASA / black |
| TILT ANGLES | -2 – 6° (with mounting base) 2 – 10° (without mounting base) |
| PROTECTION DEGREE | IP54 |
| TEMPERATURE RANGE | -22 – 140 °F if powered 14 – 140 °F without power |
| HUMIDITY | 0 – 95% non-condensing |
| VIBRATIONS | < 2 G |
| COMPLIANCE | IEC 60335-2-103 ISO 13849-1 (PL “d”); IEC 61508 (SIL2) |