Home
Shop

BEA Sensors 10MSRR-SGPS Touchless restroom kit, with power supply – single gang

$1,050.00

Buy Now
SKU:10MSRR-SGPS

Touchless restroom kit, with power supply – single gang

POWER SUPPLY ENCLOSURE
Agency listings UL294, cUL, CSFM, MEA, NFPA 101
Input 115VAC, 60Hz, 0.6A.
Output 12VDC or 24VDC 1.75A continuous
Supervision AC fail supervision Dry trigger output
Fire alarm interface Dry trigger input
Visual indicators AC input and DC output LED indicators
Enclosure dimensions 13.5” × 13” × 3.25” (342.9mm × 330.2mm × 82.6mm)
   
LOGIC MODULE
Supply voltage 12 − 24 VAC/VDC ±10%
Current consumption 30 − 130 mA (DRY output)
Temperature rating -15 − 150 °F (-26 − 150 °C) If powered by AC voltage and using WET output to convert to DC voltage and current draw of device is greater than 0.9 A, the upper temperature range is 130 °F (54 °C).
Input Input 1, 2, 3, 4 WET input DRY contact 5-24 VAC/VDC ±10%
Contact rating relay 1 (DRY) relay 1 (WET) relay 2 relay 3 3 A @ 24 VAC or 30 VDC 1 A 3 A @ 24 VAC or 30 VDC 1 A @ 24 VAC or 30 VDC
Dimensions 5.2” x 2.2” x 1” (133 mm x 55 mm x 25 mm)
Housing ABS - white translucent
   
MS42
Technology microwave motion sensor
Radiated frequency 24.150 GHz
Detection range 4 – 24” (adjustable)
Supply voltage* 12 – 24 VAC ±10% 12 – 24 VDC +30% / -10%
Power consumption < 1.5W
Output* max. voltage max. current Electronic relay (galvanic isolation - polarity free) 42 VDC / 30 VAC 100 mA
Temperature range -20 – 55 °C
IP rating IP55
Certification EMC: 2004/108/EC FCC: G9B-210161 IC: 4680A-210161
   
DOOR POSITION SWITCH
Gap distance 0.43”
Loop open
Reed form N.C.
Max. contact rating 3 W
Max. initial contact resistance 100 mΩ
Max. switching voltage 30 VAC/VDC
Max. switching current 0.2 A
Color white
Leads length 12”, 22 AWG
Contact size 1.1” (L) × 0.37” (W) × 0.19” (H)
Weight 8 lbs
Back to Top